Products

View our ISO 90001/2008 Certficate

Single Pair Thermocouple and Extension Wires

High Temperature Fiberglass Insulated Parallel Construction with Stainless Steel Braid

  • Excellent for high temperature applications up to 900°F for Fiberglass, 1475°F for High Temperature Fiberglass and 2550°F for Ceramic Fiber.
  • Suitable for use at normal air ambient temperatures where there is a possibility of a hot spot which might damage lower rated cables such as PVC or PFA
  • We offer a wide variety of constructions from simple lapped and Fibreglass braided to stainless steel braided types in virtually all the thermocouple combinations
High Temperature Fibreglass Parallel Twin with Stainless Steel Braid
One pair of solid conductors. Each conductor double high temperature glass fiber lapped, double high temperature glass fiber braided and varnished. Parallel construction, high temperature glass fiber braided and varnished. Stainless steel wire braided overall.

High Temperature Fibreglass Parallel Twin with Stainless Steel Braid
One pair of stranded conductors. Cores double HT glass fibre lapped, braided and varnished. Pair laid flat, HT glass fibre braided & varnished. Stainless steel wire braided overall.

Stock Number C78 C79 C70 C80
Wire Type (number of strands x AWG)   Solid Solid Solid 13
Wire Size - AWG   24 20 16 32
Insulation   High Temp Fibreglass High Temp Fibreglass
Number of Pairs   1 1
Conductor Configuration   Parallel Parallel
Shielded   Yes Yes
Insulation   High Temp Fibreglass High Temp Fibreglass
Insulation
Rating
ºF   +1472 +1472
ºC   +800 +800
Color Coding   Yes Yes
Physical
Properties
Abrasion Resistance   Good Good
Moisture Resistance   Fair Fair
Typical Weight (lbs/1000ft)
excl reel
  4 9 11 4
Diameter under Armor (inches)  
Diameter over Armor (inches)  
Overall
Diameter
inches   0.12" x 0.16" 0.12" x 0.16" 0.20" x 0.28" 0.12" x 0.16"
mm     3x4 3x4 5x7 3x4
Popular Order Codes

C78KX, C78JX, C78NX

C79KX

C70KX, C70TX, C70JX, C70RCA

C80KX

Notes



All dimensions are approximate
Impregnation retained up to 350°F.
Above this temperature the integrity of
the cable is maintained to the upper
insulation rating limit provided the cable is not flexed particularly when cold.
Above 350°F the integrity of the cable is maintained to the upper insulation rating limit provided the cable is not flexed particularly when cold.