Other Thermocouple and RTD Connectors

BTS Interconnecting Barrier Terminal Blocks

Application
These interconnecting Barrier Terminal Blocks are suitable for use with all thermocouple types as well as Copper for other sensors such as RTD’s. Each single block comes complete with terminal lugs and end caps. All are color coded as shown for easy identification and are temperature rated to 425ºF.

TL Spare Terminal Lugs

Application
Whilst BTS terminal blocks are supplied complete with terminal lugs, it is possible to purchase them separately as spares or for a new application.
Construction
All lugs are made from the relevant thermocouple material. Terminal Lugs are spares for the Barrier Terminal Strip itself.

Enquiry Form

BTS Thermocouple Type


Color Code


Quantity Required


TL Terminal Lug 1


TL Terminal Lug 2


Quantity Required


Contact Details


Company Name


Your Name


Email


Telephone


Additional Information


If your enquiry is for more than one style of connector, please email us with your requirements or use the box below



Send Enquiry  

1 Thermocouple Type Temperature Range (ºF) Temperature Range (ºC)
K Nickel Chromium vs
Nickel Aluminium
+32ºF to 2012ºF 0ºC to +1260ºC
T Copper vs Constantan -301ºF to 572ºF 0ºC to +370ºC
J Iron vs Constantan +32ºF to +1400ºF 0ºC to +760ºC
N Nicrosil vs Nisil +32ºF to 2012ºF 0ºC to +1260ºC
E Nickel Chromium vs Constantan +32ºF to +1600ºF 0ºC to +870ºC
R Platinum - 13% Rhodium vs
Platinum
+32ºF to +2700ºF 0ºC to +1480ºC
S Platinum - 10% Rhodium vs
Platinum
+32ºF to +2700ºF 0ºC to +1480ºC
B Platinum - 30% Rhodium vs
Platinum 6% Rhodium
+1600ºF to +3100ºF +212ºF to +3308ºF
Temperature ranges refer to the operating range of the thermocouple type.
The temperature range of the connector will be as stated.
Please refer to the product description for more details.