These are suitable for general use and as replacement elements for industrial and high temperature thermocouples similar to our Types 13 and 14 described on pages 49 and 51. Type 2 assemblies are available for thermocouple types K, T, J, N and E with insulators in Aluminous Porcelain and for types R, S and B with insulators in Recrystallised Alumina. The length of insulators is 1", 2" or 4" depending on the application and availability. Insulators with 4 bores are available for duplex applications, please contact us for further details.

Enquiry Form

1. Thermocouple Type


2. Style Number


3. Overall Length


 ft*

4. Optional Thermocouple Plug


5. Quantity Required


Contact Details


Company Name


Your Name


Email


Telephone


Additional Information


If your enquiry is for more than one style of sensor, please email us with your requirements or use the box below



Send Enquiry  

1 Thermocouple Type Temperature Range (continuous) Temperature Range
(short term)
K Nickel Chromium vs
Nickel Aluminium
32°F to +2010°F -290°F to +2460°F
T Copper vs Constantan -300°F to +570°F -420°F to +750°F
J Iron vs Constantan +68°F to +1290°F -290°F to +1380°F
N Nicrosil vs Nisil 32°F to +2010°F -450°F to +2370°F
E Nickel Chromium vs Constantan 32°F to +1470°F -40°F to +1650°F
R Platinum - 13% Rhodium vs
Platinum
32°F to +2820°F -60°F to +3180°F
S Platinum - 10% Rhodium vs
Platinum
32°F to +2910°F -60°F to +3090°F
B Platinum - 30% Rhodium vs
Platinum 6% Rhodium
+212°F to +2910°F +212°F to +3310°F
Temperature ranges refer to the thermocouple type.
The temperature range of the sensor may deviate from the above,
please refer to the product description for more details