Products

Bearing / Embedded Thermocouple (Type 6)

General Purpose Thermocouples - Bearing / Embedded Thermocouples

A range of fast response miniature embedded (also known as embedment) thermocouple sensors designed for surface temperature measurements in general industrial applications such as in bearing shoe applications to give a reliable indication of bearing wear and oil film breakdown through continuous monitoring of temperatures. These tip sensitive thermocouples have an operating temperature range of -25°C to +250°C and can be supplied with a pressure tested oil seal barrier to prevent leakage. Standard assemblies are easy to install in drilled holes for general temperature sensing applications, whereas the spring loaded ‘top hat’ style assemblies are inserted into a milled hole with a retaining clip, pushed down to compress the spring and retain the sensor against the surface being monitored.
  • Fast response and cost-effective solution to bearing temperature monitoring
  • Standard (Cap) or 'Top Hat' style tips
  • Pressure tested (minimum 5bar/75psi for at least one hour) Oil Seal Barrier (feedthrough) available
  • Stainless steel and phosphor bronze tip materials
  • Sensors and Oil seals are rated for use up 480°F
  • color coded to ANSI MC96.1 or IEC584.3
  • See detailed information on how a thermocouple works

Bearing Thermocouple Enquiry Form

1. Thermocouple Type
2. Tip Style

Illustration Select
STANDARD (Cap) Style
TOP HAT Style
Duplex Element Required? (please tick box)
3a. Standard (Cap) Style Material
SS - Stainless Steel
PB - Phosphor Bronze
3b. SS Cap Style Sizes (d1 x L1)

3. PB Cap Style Sizes (d1 x L1)

3. Top Hat Dia. (d1) and Material

4. Oil Seal Barrier

Illustration Select
Not Required
Required
5. Cable Length
5a. Oil Seal Dia.

5b. Oil Seal Length
5c. Cable Length - Tip to Oil Seal
5d. Cable length - Oil Seal to Cold End
6. Optional Thermocouple Plug
7. color Code

8. Quantity Required

Contact Details

Company Name


Your Name


Title/Dept.


Email


Telephone


Additional Information

If your enquiry is for more than one style of sensor, please email us with your requirements or use the box below



Send Enquiry  
See our full range of thermocouple probes

BACK TO TOP
Products

Contact Us

About TC

FREE Guide

Privacy Policy

Terms and Conditions

Sitemap
FREE Wallchart Guide

Join over 500,000 engineers and buyers who have already received our FREE 74 page A3 Guide to Thermocouple and Resistance Thermometry

Company Name
  Address 1
Your Name
  Address 2
Title / Dept.
  State
Email
  ZIP Code
Telephone
  Country
Company Name
Your Name
Title / Dept.
Address 1
Address 2
State
ZIP Code
Country
Email
Telephone

We will only ever use the information you provide to occasionally contact you regarding our products and we will never disclose your details to a third party. Our privacy policy can be viewed here



I agree to the terms and conditions listed in the Privacy Policy

View our ISO 90001/2008 Certficate



© 2006- TC Measurement and Control Inc., PO Box 685, Hillside, IL 60162, United States
Tel.: 877 249 1777, Fax: 708 449 0777, Email: info@tc-inc.com



1 Thermocouple Type Temperature Range (continuous) Temperature Range
(short term)
K Nickel Chromium vs
Nickel Aluminium
32°F to +2010°F -290°F to +2460°F
T Copper vs Constantan -300°F to +570°F -420°F to +750°F
J Iron vs Constantan +68°F to +1290°F -290°F to +1380°F
N Nicrosil vs Nisil 32°F to +2010°F -450°F to +2370°F
E Nickel Chromium vs Constantan 32°F to +1470°F -40°F to +1650°F
Temperature ranges refer to the thermocouple type.
The temperature range of the sensor may deviate from the above,
please refer to the product description for more details