Thermocouple Wire - Heat Resistant PVC Insulated Twisted Pair with Armor
Thermocouple Wire and Extension Wire - Single Pair
Heat Resistant PVC Insulated Twisted Pair with Armor Thermocouple Wire
|
||||||
HR PVC Twisted Pair with Armor
One twisted pair of solid conductors HR PVC insulated. Shielded with Mylar aluminum tape in contact throughout with a bare tinned copper drainwire. HR PVC inner jacket insulation with steel wire armor and HR PVC insulation overall. |
HR PVC Twisted Pair with Armor
One twisted pair of stranded conductors HR PVC insulated. Shielded with Mylar aluminum tape in contact throughout with a bare tinned copper drainwire. HR PVC inner jacket insulation with steel wire armor and HR PVC insulation overall. |
|||||
Stock Number | A90 | A95 | ||||
Wire Type (number of strands x AWG) | Solid | 23x32 | ||||
Wire Size - AWG | 16 | 19 | ||||
Insulation | Heat Resistant PVC | Heat Resistant PVC | ||||
Number of Pairs | 1 | 1 | ||||
Conductor Configuration | Twisted | Twisted | ||||
Shielded | Yes | Yes | ||||
Insulation | Heat Resistant PVC | Heat Resistant PVC | ||||
Insulation Rating (ºF) |
Continuous | -22 to +220 | -22 to +220 | |||
Short Term | — | — | ||||
Color Coding | Yes | Yes | ||||
Physical Properties |
Abrasion Resistance | Good | Good | |||
Moisture Resistance | Very Good | Very Good | ||||
Typical Weight (lbs/1000ft) excl reel |
204 | 150 | ||||
Diameter under Armor (inches) | 0.28" | 0.24" | ||||
Diameter over Armor (inches) | 0.35" | 0.31" | ||||
Overall Diameter |
inches | 0.47" | 0.43" | |||
mm | 12 | 11 | ||||
Popular Order Codes | A90K |
A90KX, A90KCB, A90TX |
||||
Notes All dimensions are approximate |
Round cross section. Rejects electromagnetic and electrostatic interference. Armored for mechanical strength. |
Round cross section. Rejects electromagnetic and electrostatic interference. Armored for mechanical strength. |