Thermocouple Wire - PFA Insulated Twisted
Thermocouple Wire and Extension Wire - Single Pair
PFA Insulated Twisted Thermocouple Wire
|
||||||||
PFA Twisted
One pair of solid conductors PFA insulated. Pair twisted and PFA sheathed. |
PFA Twisted
One pair of stranded conductors PFA insulated. Pair twisted and PFA sheathed. |
|||||||
Stock Number | B25 | B35 | B55 | B65 | ||||
Wire Type (number of strands x AWG) | Solid | Solid | 7x32 | 13x32 | ||||
Wire Size - AWG | 24 | 20 | 24 | 21 | ||||
Insulation | PFA | PFA | ||||||
Number of Pairs | 1 | 1 | ||||||
Conductor Configuration | Twisted | Twisted | ||||||
Shielded | No | No | ||||||
Insulation | PFA | PFA | ||||||
Insulation Rating (ºF) |
Continuous | -100 to +480 | -100 to +480 | |||||
Short Term | +570 | +570 | ||||||
Color Coding | Yes | Yes | ||||||
Physical Properties |
Abrasion Resistance | Good | Good | |||||
Moisture Resistance | Very Good | Very Good | ||||||
Typical Weight (lbs/1000ft) excl reel |
7 | 21 | 7 | 14 | ||||
Diameter under Armor (inches) | — | — | ||||||
Diameter over Armor (inches) | — | — | ||||||
Overall Diameter |
inches | 0.12" | 0.12" | 0.12" | 0.12" | |||
mm | 3 | 3 | 3 | 3 | ||||
Popular Order Codes | B25KX, B25TX, B25JX, B25EX, B25RCA B35KX, B35TX, B35JX, B35RCA |
B55KX, B55TX, B55JX, B55NX, B55RCA B65KX, B65TX, B65JX, B65RCA |
||||||
Notes All dimensions are approximate |
Round cross section (pair lay visible through sheath). Rejects electromagnetic interference. Gas, steam and water tight insulation. | Round cross section (pair lay visible through sheath). Rejects electromagnetic interference. Gas, steam and water tight insulation. |