Stock Number | C10 | C20 | C30 | C40 | C50 | C51 | C52 | C53 | ||||
Wire Type (number of strands x AWG) | Solid | Solid | Solid | 7x32 | 13x32 | 23x32 | 32x32 | 40x32 | ||||
Wire Size - AWG | 28 | 24 | 20 | 24 | 21 | 19 | 16 | 16 | ||||
Insulation | Fiberglass | Fiberglass | ||||||||||
Number of Pairs | 1 | 1 | ||||||||||
Conductor Configuration | Parallel | Parallel | ||||||||||
Shielded | No | No | ||||||||||
Insulation | Fiberglass | Fiberglass | ||||||||||
Insulation Rating (ºF) |
Continuous | +896 | +896 | |||||||||
Short Term | +1000 | +1000 | ||||||||||
Color Coding | Yes | Yes | ||||||||||
Physical Properties |
Abrasion Resistance | Fair | Fair | |||||||||
Moisture Resistance | Fair | Fair | ||||||||||
Typical Weight (lbs/1000ft) excl reel |
7 | 7 | 14 | 7 | 14 | 21 | 28 | 28 | ||||
Diameter under Armor (inches) | — | — | ||||||||||
Diameter over Armor (inches) | — | — | ||||||||||
Overall Diameter |
inches | 0.04" x 0.08" | 0.08" x 0.12" | 0.08" x 0.12 | 0.08" x 0.12" | 0.08" x 0.12" | 0.12" x 0.16" | 0.12" x 0.16" | 0.16" x 0.20" | |||
mm | 1x2 | 2x3 | 2x3 | 2x3 | 2x3 | 3x4 | 3x4 | 4x5 | ||||
Popular Order Codes | C10KX, C10TX, C10JX, C10RCA C20KX, C20TX, C20JX, C20NX, C20RCA C30KX, C30TX, C30JX, C30NX, C30RCA |
C40KX, C40TX, C40JX, C40NX, C40EX, C40RCA C50KX, C50TX, C50JX, C50EX, C50RCA C51KX, C51TX, C51JX, C51NX, C51RCA, C51CU C52KX, C52TX, C52JX, C52RCA C53KX, C53TX, C53JX, C53RCA |
||||||||||
Notes All dimensions are approximate |
Impregnation retained up to
350°F. Above this temperature
the integrity of the cable is
maintained to the upper insulation rating limit provided the cable is not flexed particularly when cold. |
Impregnation retained up to 350°F. Above this temperature the integrity of the cable is maintained to the upper insulation rating limit provided the cable is not flexed particularly when cold. |