Thermocouple Wire - Fiberglass Insulated Parallel Construction with Stainless Steel Braid

Thermocouple Wire and Extension Wire - Single Pair
Fiberglass Insulated Parallel Construction with Stainless Steel Braid Thermocouple Wire

  • Excellent for high temperature applications up to 900°F for Fiberglass, 1475°F for High Temperature Fiberglass and 2190°F for Ceramic Fiber.
  • Suitable for use at normal air ambient temperatures where there is a possibility of a hot spot which might damage lower rated cables such as PVC or PFA
  • We offer a wide variety of constructions from simple lapped and Fiberglass braided to stainless steel braided types in virtually all the thermocouple combinations
Fiberglass Parallel Twin with
Stainless Steel Braid

One pair of stranded conductors. Cores double glass fiber lapped, braided and varnished. Pair parallel, glass fiber braided and varnished. Stainless steel wire braided overall.

Stock Number C60 C65 C66 C67 C68
Wire Type (number of strands x AWG)   7x32 13x32 23x32 32x32 40x32
Wire Size - AWG   24 21 19 16 16
Insulation   Fiberglass
Number of Pairs   1
Conductor Configuration   Parallel
Shielded   No
Insulation   Fiberglass
Insulation
Rating (ºF)
Continuous   +896
Short Term   +1000
Color Coding   Yes
Physical
Properties
Abrasion Resistance   Good
Moisture Resistance   Fair
Typical Weight (lbs/1000ft)
excl reel
  14 21 28 34 34
Diameter under Armor (inches)  
Diameter over Armor (inches)  
Overall
Diameter
inches   0.12" x 0.16" 0.12" x 0.16" 0.16" x 0.20" 0.16" x 0.20" 0.16" x 0.24"
mm     3x4 3x4 4x5 4x5 4x6
Popular Order Codes

C60KX, C60TX, C60JX, C60NX, C60RCA

C65KX, C65TX, C65JX, C65RCA

C66KX, C66TX, C66JX, C66NX, C66RCA

C67KX, C67TX, C67JX, C67RCA

C68KX, C68TX, C68JX, C68RCA

Notes



All dimensions are approximate
Impregnation retained up to 350°F. Above this temperature the integrity of the cable is maintained to the upper insulation rating limit provided the cable is not flexed particularly when cold.

Frequently Asked Questions

  • What is a thermocouple cable, and why is it important?
    A thermocouple wire is used to connect a thermocouple sensor to measurement equipment. It transmits the temperature signal generated by the thermocouple, ensuring accurate readings are maintained. The choice of cable material (such as PVC, PFA, or fiberglass) affects the cable's durability, temperature range, and resistance to environmental factors, making it critical to select the right one for your application.
  • What are the different types of thermocouple cables available?
    Thermocouple cables are categorised into thermocouple and extension types. Thermocouple grade cables use the same material as the thermocouple and are used to make the sensing part of the thermocouple, designated by two letters such as Type KK (Type K), Type JJ (Type J), and Type TT (Type T) etc. Extension grade wire can only be used to extend ther thermocouple to the instrumentation, these are designated as type KX, TX, JX etc.
  • What insulation materials are available for thermocouple cables?
    We stock over 7 million feet of thermocouple cable with a variety of insulation material, including PVC, PFA, fibreglass, ceramic fiber, XLPE, and silicone rubber. PVC (220ºF) is a good general purpose cable, PFA (480ºF) has good chemical and oil resistance, Fibreglass (890ºF) is good for industrial use at higher temperatures and Silicon Rubber (390ºF) is a good choice if a very flexible cable is required.

Thermocouple Wire Enquiry Form

1. Stock Number

2. Wire Details

3. Color Code

4. Quantity Required

 in feet
Contact Details

Company Name


Your Name


Email


Telephone


Additional Information

If your enquiry is for more than one style of Wire, please email us with your requirements or use the box below



Send Enquiry  
thermocouple wire
Click here for Our Full Range of Thermocouple Wires and Cables