AMS2750 Approved Vacuum Furnace Thermocouple with Miniature Jack
AMS2750 Approved Thermocouples for Vacuum Furnaces
with Miniature Jack
Related Products
Miniature Plug
Ceramic Sheathed Vacuum Thermocouples
Type 40/41 assemblies incorporate an integral Spectite® seal and are ideal for vacuum furnace applications. The Spectite® vacuum seal is rated to 5 x 10-6 torr with low leak rates (better than or equal to 1 x 10-6 scc/sec. under 1 Atm @ 20ºC). These sensors can be supplied to all recognised standards and tolerances when combined with our UKAS calibration services. They are available in simplex and duplex junction styles with an optional test sensor hole for calibration / survey work. A wide range of support tube fittings for attachment into the process is available.
Type 40/41 assemblies incorporate an integral Spectite® seal and are ideal for vacuum furnace applications. The Spectite® vacuum seal is rated to 5 x 10-6 torr with low leak rates (better than or equal to 1 x 10-6 scc/sec. under 1 Atm @ 20ºC). These sensors can be supplied to all recognised standards and tolerances when combined with our UKAS calibration services. They are available in simplex and duplex junction styles with an optional test sensor hole for calibration / survey work. A wide range of support tube fittings for attachment into the process is available.
- Vacuum seal rated 5 x 10-6 torr
- Low leak rates
- Integral Spectite® seal on internal wire maintains vacuum even if sheath is damaged
- Wide operating temperature range up to 2910°F
- Wide range of attachments for process installation
- Simplex and Duplex versions available
- UKAS and In-House calibration options available to all major international and industry specific standards
- Flexible tagging options available for clear traceability
Calibration Accuracies:
Code | Standard | Accuracy Supplied | Certification |
IEC1 | IEC 60584.1 Class 1 | Types K/N: ±1.5ºC (-40 to +375ºC) or 0.4% (375 to 1000ºC) Types R/S: ±1.0ºC (0 to 1100ºC) or 1ºC + 0.3% of temperature above 1100ºC (1100 to 1600ºC) |
TC offer both UKAS and In-House (traceable to national standards) calibrations to all major international standards up to 1590°C. Our laboratory is fully accredited to ISO17025 and our reports are designed with the requested standard in mind. Our sales engineers are on hand to discuss any requirements so please do not hesitate to contact us for more details. |
AMS1 | AMS2750 | Types K/N: ±1.1ºC or 0.4% Types R/S: ±1.0ºC or 0.25% (whichever is greater) Type B: ±1.0ºC or 0.25% (whichever is greater) |
|
BAC2 | BAC5621 | ±1.1ºC <538ºC or 0.4% of reading >538ºC |