Products

High Temperature Thermocouple with Standard Plug

High Temperature Metal Sheathed Thermocouples (Type 27)

These high temperature thermocouples are used in applications where other thermocouples would fail due to excessive heat or severe environments. Utilising specialist exotic sheath materials such as Platinum 10% Rhodium, Molybdenum and Tantalum they can be used in service temperatures up to 4170°F. The combination of conductor, insulation material and sheath must be carefully selected to suit your process environment, service temperature and installation requirements (ie. whether the probe is flexible or not). Our experienced sales team are on hand to assist where required so please contact us if help is required.
  • Typically used with high temperature thermocouple types R, S, B, C and D
  • Temperatures up to 3990°F (continuous) or 4170°F (short term)
  • Semi-Rigid (mineral insulated) and Rigid (tube) styles available
  • Terminated in a standard round pin plug, rated to 410°F, 570°F, 790°F or 1110°F
  • Calibration service for oxidizing and inert environments up to 3970°F

Code Sheath Material Operational Properties MI (Semi-Rigid)
Tube (Rigid)
Insulation Material Thermocouple Types Available Sheath Diameters (mm) Max.
Continuous Temperature
600

Inconel 600®

Suitable for use in inert, vacuum and oxidizing environments.
Minimum bend radius: 5 x sheath diameter.

Not recommended for use above 1470°F in oxidising atmospheres. Do not use in sulphur bearing atmospheres above 1020°F.
Semi-Rigid MgO R, S and B 0.040”, 0.062”, 0.125”, 0.188” and 0.250” 2140°F
600T Inconel 600® As above. Do not bend. Rigid Al2O3 R, S and B 0.125”, 0.188” and 0.250” 2140°F
P10R Platinum 10% Rhodium Suitable for use in inert and oxidizing environments.
Minimum bend radius: 10 x sheath diameter.
Semi-Rigid MgO R, S and B 0.040” and 0.062” 2820°F
TAN Tantalum Suitable for use in inert and vacuum environments.
Minimum bend radius: 5 x sheath diameter.
Semi-Rigid MgO, Al2O3, HfO2 R, S, B, C and D 0.040”, 0.062” and 0.125” 3990°F
NIO Niobium 1% Zirconium Suitable for use in inert and vacuum environments.
Minimum bend radius: 10 x sheath diameter.
Semi-Rigid MgO, Al2O3, HfO2 R, S, B, C and D 0.062” and 0.125” 3990°F
MOL Molybdenum Suitable for use in inert, vacuum and reducing environments.
Do not bend.
Rigid MgO, Al2O3, HfO2 R, S, B, C and D 0.062”, 0.125”, 0.188” and 0.250” 3630°F
CMOL Coated Molybdenum Suitable for use in inert and oxidizing environments.
Do not bend.
Rigid MgO, Al2O3, HfO2 C and D 0.062”, 0.125” and 0.250” 2910°F

High Temperature Thermocouple Enquiry Form

1. Thermocouple Type
2. Sheath Material (see above)
3. Insulation Material
4. Sheath Diameter
5. Sheath Length
 inches
6. Types of Sensing Junction

Illustration Select
INSULATED Junction
GROUNDED Junction
Duplex Element Required? (please tick box)
7. Standard Plug Style

Illustration Select
3P6 - Standard Plug
Plastic, rated to 425ºF
3P6H - Standard Plug
Plastic, rated to 570ºF (normal)

3P6UH - Standard Plug

Plastic, rated to 790ºF

3P6C - Standard Plug
Ceramic - rated to 1110ºF
8. Quantity Required


Contact Details

Company Name


Your Name


Title/Dept.


Email


Telephone


Additional Information

If your enquiry is for more than one style of sensor, please email us with your requirements or use the box below



Send Enquiry  


BACK TO TOP
Products

Contact Us

About TC

FREE Guide

Privacy Policy

Terms and Conditions

Sitemap
FREE Wallchart Guide

Join over 500,000 engineers and buyers who have already received our FREE 74 page A3 Guide to Thermocouple and Resistance Thermometry

Company Name
  Address 1
Your Name
  Address 2
Title / Dept.
  State
Email
  ZIP Code
Telephone
  Country
Company Name
Your Name
Title / Dept.
Address 1
Address 2
State
ZIP Code
Country
Email
Telephone

We will only ever use the information you provide to occasionally contact you regarding our products and we will never disclose your details to a third party. Our privacy policy can be viewed here



I agree to the terms and conditions listed in the Privacy Policy

View our ISO 90001/2008 Certficate



© 2006- TC Measurement and Control Inc., PO Box 685, Hillside, IL 60162, United States
Tel.: 877 249 1777, Fax: 708 449 0777, Email: info@tc-inc.com



1 Thermocouple Type Temperature Range (continuous) Temperature Range
(short term)
R Platinum - 13% Rhodium vs
Platinum
32 to +2820°F -60 to +3180°F
S Platinum - 10% Rhodium vs
Platinum
32 to +2910°F -60 to +3090°F
B Platinum - 30% Rhodium vs
Platinum 6% Rhodium
212 to +2910°F 212 to +3310°F
C Tungsten - 5% Rhenium vs
Tungsten - 26% Rhenium
120 to +3330°F 68 to +4170°F
D Tungsten - 3% Rhenium vs
Tungsten - 25% Rhenium
120 to +3330°F 68 to +4170°F
Temperature ranges refer to the thermocouple type.
The temperature range of the sensor may deviate from the above,
please refer to the product description for more details
2 Insulation Material Comments Max.
Temperature
MGO

Magnesium Oxide
MgO

Very hygroscopic. Used mostly in compacted sheaths. 3090°F
ALO Aluminium Oxide
Al2O3
Excellent with Platinum alloys. 2820°F
HFO Hafnium Oxide
HfO3
Comparible to Berylium Oxide and safe to handle. 3990°F
* Please refer to the Sheath Material table above for applicable diameters

INSULATED
Hot junction insulated from sheath. Gives floating output with typical insulation resistance in excess of 100 megohms

GROUNDED
Hot junction welded to sheath tip giving earthed output and faster response to temperature changes