Need a quote or advice?

Contact one of our experienced engineers

Call TC
TC Measurement & Control, Inc.

Autoclave Drain Thermocouple (Type 9B)

General Purpose Thermocouples - Autoclave Drain Thermocouples

Related Products

Standard Plug

Related Products

Standard Socket

Related Products

Miniature Plug

Related Products

Miniature Socket
Designed specifically for autoclave drain applications, these sensors incorporate similar manufacturing techniques to the load sensor which results in a very reliable sensor being produced.

Available in thermocouple types T or K, they can be supplied as simplex or duplex assemblies and comprise of a stainless steel sensor tip with a length of flying leads that are oversheathed with silicone rubber.

See detailed information on how a thermocouple works

Autoclave Thermocouple Enquiry Form

1. Thermocouple Type
2. Sheath Diam. 'd1'
 inches
3. Sheath Length 'L1'
 inches
4. Types of Sensing Junction


Illustration Select
INSULATED Junction
GROUNDED Junction
Duplex Element Required? (please tick box)
Triplex Element Required? (please tick box)
5. Wire Length 'L2'
 ft*
6. Optional Thermocouple Plug
7. Quantity Required

Contact Details

Company Name


Your Name


Email


Telephone


Additional Information

If your enquiry is for more than one style of sensor, please email us with your requirements or use the box below



Send Enquiry  
See our full range of thermocouple probes

1 Thermocouple Type Temperature Range (continuous) Temperature Range
(short term)
K Nickel Chromium vs
Nickel Aluminium
32°F to +2010°F -290°F to +2460°F
T Copper vs Constantan -300°F to +570°F -420°F to +750°F
Temperature ranges refer to the thermocouple type.
The temperature range of the sensor may deviate from the above,
please refer to the product description for more details

INSULATED
Hot junction insulated from sheath. Gives floating output with typical insulation resistance in excess of 100 megohms

GROUNDED
Hot junction welded to sheath tip giving earthed output and faster response to temperature changes